Telephone: +86 15692351914 /15726569531 (whatsapp)     Email: info@haiyufield.com
  HOME > PRODUCTS > Level solutions > Radar Level Transmitter
26G Radar Level Meter

Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave 

exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to 

the electronic circuit automatically converted into level signals (because the microwave propagation speed, 

electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

26.png


CONTACT US
Product Details


26G High Frequency Radar Leve Meter

The characteristics of 26G radar level meter:

Ø  Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

Ø  Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the 

temperature and pressure changes.

Ø  Serious dust environment on the high level meter work has little effect.

Ø  A shorter wavelength, the reflection of solid surface inclination is better.

Ø  Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

Ø  The measuring range is smaller, for a measurement will yield good results.

Ø  High signal-to-noise ratio, the level fluctuation state can obtain better performance.

Ø  High frequency, measurement of solid and low dielectric constant of the best choice.

Product  Introduction

                                                                                                 
HYRD901                                                                                              
Application All kinds of corrosive liquid

901.jpg

Measuring Range10 meters

Process Connection Thread, Flange

Process  Temperature -40~130

Process Pressure -0.1~0.3 MPa

Accuracy ± 5mm    

Protection Grade IP67 

Frequency Range 26GHz

Supply2-wireDC24V/ 4-wireDC24V /AC220V

Signal Output4... 20mA /HART 2-wire / 4-wire

RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

                                                            Explosion-proof GradeExiaC T6 Ga/ Exd C T6 Gb


HYRD902

902.jpg


ApplicationSlightly corrosive liquid

Measuring Range30 meters

Process ConnectionThread, Flange

Process  Temperature-40~130(Standard type)

-40~230(High temperature type

Process Pressure-0.1 ~ 4.0 MPa

Accuracy ± 3mm  

Protection GradeIP67  

Frequency Range 26GHz

Supply2-wireDC24V/ 4-wireDC24V /AC220V

Signal Output4... 20mA /HART2-wire / 4-wire

              RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

Explosion-proof GradeExiaC T6 Ga/ Exd C T6 Gb 


HYRD903

903.jpg


ApplicationSolid material, Strong dust

          easy to crystallize, condensation occasion

Measuring Range 70 meters

Process ConnectionUniversal Flange

Process  Temperature-40~130(Standard type)

-40~230(High temperature type

Process Pressure-0.1~4.0 MPa (Flat flange)

-0.1~0.3MPa (Universal flange)

Protection Grade IP67  

Accuracy ±15mm   

Frequency Range26GHz

Supply2-wireDC24V/ 4-wireDC24V /AC220V

Signal Output4... 20mA /HART 2-wire / 4-wire

              RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

Explosion-proof GradeExiaC T6 Ga/ Exd C T6 Gb

HYRD904

904.jpg

ApplicationSolid material, Strong dust,

                     easy to crystallize, condensation occasion

Measuring  Range80 meters

Process  ConnectionThread, Universal Flange

Process  Temperature-40~130(Standard type)

-40~230(High temperature type

Process  Pressure-0.1 ~ 0.3 MPa

Measurement  Accuracy ±15mm  

Protection  GradeIP67  

Frequency  Range 26GHz  

Supply2-wireDC24V/ 4-wireDC24V /AC220V  Signal Output4... 20mA / HART (2-wire / 4-wire )

              RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

Explosion-proof GradeExiaC T6 Ga /Exd C T6 Gb 

HYRD905

905.jpg

ApplicationSolid particles, Powder

Measuring Range30 meters

Process ConnectionThread, Flange

Process  Temperature-40~130(Standard type)

-40~230(High temperature type

Process Pressure-0.1 ~ 4.0 MPa (Flat flange)

                                -0.1 ~ 0.3 MPa (Universal Flange)

Accuracy±15mm  

Protection GradeIP67

Frequency Range26GHz

Supply2-wireDC24V/ 4-wireDC24V /AC220V

Signal Output4... 20mA /HART (2-wire / 4-wire )

                         RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

Explosion-proof GradeExia C T6  Ga /Exd  C T6 Gb

HYRD906

QQ图片20181107165935.jpg

ApplicationHygienic liquid storage,

Corrosive container

Measuring Range20 meters

Process ConnectionFlange

Medium Temperature-40~100

Process Pressure-0.1~1.6 MPa

Accuracy± 3mm  

Protection GradeIP67

Frequency Range26GHz 

Supply2-wireDC24V/ 4-wireDC24V /AC220V

Signal Output4... 20mA/HART (2-wire / 4-wire )

              RS485/ Modbus

Outer CoveringAluminum / Plastic / Stainless steel

Explosion-proof GradeExia C T6 Ga /Exd C T6 Gb

Installation Size

HYRD901

                  90111.png

HYRD902

                   90222.png

HYRD903

                 90333.png               

HYRD904

                  90444.png

HYRD905             

                   90555.png

HYRD906

                  90666.png

Technical Parameters


Process Connection             Thread G1½″A / Thread 1½″ NPT /  Flange

Antenna Material                   Stainless Steel  /  PTFE

The outer shell 

The seal between the shell and the shell cover                 Silicone rubber

Casing window                                                                   Polycarbonate

The ground terminal                                                           Stainless steel

 

The power supply voltage

Two wire system             

The standard type                   (16 ~ 26) V DC

Intrinsically safe                      (21.6 ~ 26.4) V DC  

Power dissipation                    max 22.5mA / 1W    


(22.8 ~ 26.4) V DC       2-wire system

(198 ~242)V AC   4-wire system / 110V AC    4-wire system

 

The cable parameters

Cable entrance / plug           1  M20xl.5 cable entrance

                                             1  blind plug

Terminal                               Conductor cross section 2.5mm² 

 

Output parameters

The output signal                              (4 ~ 20) mA/RS485

Communication protocol                   HART

Resolution                                        1.6μA

Fault signal                                       Constant current output; 20. 5mA

22mA

3.9mA

The integral time                               (0 ~ 36) s, adjustable

 

Blind area                                 the ends of the antenna

 

The maximum distance measurement                 

901                        10 meters   Liquid type

902                        30 meters   Liquid type

902T                      20 meters   Liquid type

903                        70 meters   Solid type

904                        80 meters   Solid type

                                                   905                        30 meters   Solid type

                                                   906                        20 meters   Liquid type

 Microwave frequency                                              26GHz

 

Communication interface                                       HART communication protocol

 

The measurement interval       about 1 second (depending on the parameter settings)

 

Adjust the time                          about 1 second (depending on the parameter settings)

 

Display resolution                    1 mm


Working storage and transportation temperature                          (-4080)


Process temperature (the temperature of the antenna part)            

 901                                     (-40130)

 902/902T/903/904/905       (-40130) Standard type / (-40230)  High temperature type

 906                                     (-40100)   

Pressure                                     Max.4MPa

Seismic                                       Mechanical vibration l0m/s², (10 ~ 150) Hz



Feedback

CONTACT US

Tel: +86-535-4601431
Email: info@haiyufield.com
Add: No.6 Aokema Street Laishan District,Shandong, China
Copyright © 2008-2020 HY field instrument co.,Ltd All Rights Reserved.