Part of pulse signal reflection along the cable or rod probe conduction to the instrument of electronic circuit, a microprocessor to signal processing, to identify the microwave pulses are generated on the material surface echo. Echo recognition is completed by the pulse software, from the material surface distance between D and T pulse is proportional to the time travel:
D=C×T/2
Where C is the speed of light
Because of the air tank is a known distance E, L
L=E-D
HYRD701
Suitable medium: liquid, solid powder
Should use: Liquid and solid powder measurement, complex process conditions
Explosion-proof certification: Exib IIC T6 Gb/Exd IIC T6 Gb
Measuring range ; 30m liquid, 15 m solid
Frequency:500MHz-1.8GHz
Day line: Single cable or single rod antenna Measurement precision:±3mm
Process temperature:(-40~250) Process pressure:(-0.1~4)MPa
The signal output:(4~20)mA/HART The scene display: four LCD
Power source: two line (DC24V) / four line (DC24V/AC220V)
Shell: Aluminum Process connection: thread / flange (optional)
HYRD702
Suitable medium: Liquid, especially strong corrosive liquid
Should use: Measurement of acid, alkali and other corrosive media
Explosion-proof certification: Exib IIC T6 Gb/
Exd IIC T6 Gb
measuring range ;20m
Frequency:500MHz-1.8GHz
Day line: PTFE sealing cable or rod antenna Measurement precision:±10mm
Process temperature:(-40~180)℃ Process pressure:(-0.1~4)MPa
The signal output::(4~20)mA/HART The scene display: four LCD
Power source: two line (DC24V) / four line (DC24V/AC220V)
Shell: Aluminum Process connection: thread / flange (optional)
HYRD703
Suitable medium: Solid powder
Should use: Measurement of cement silo powder Fly ash powder measurement
Explosion-proof certification: Exib IIC T6 Gb/ Exd IIC T6 Gb
measuring range ;30m
Frequency:500 MHz -1.8GHz
Day line:Double cable type antenna Measurement precision:±5mm
Process temperature:(-40~250)℃ Process pressure:(-0.1~4)MPa
The signal output::(4~20)mA/HART The scene display: four LCD
Power source: two line (DC24V) / four line (DC24V/AC220V)
Shell: Aluminum Process connection: thread / flange (optional)
HYRD704
Suitable medium: Liquid, especially the low dielectric constant of the liquid
Should use: Measurement of deionized water, deoxygenated water and other liquids
Explosion-proof certification: Exib IIC T6 Gb /Exd IIC T6 Gb
Measuring range :6m Frequency:500MHz-1.8GHz
Day line:Coaxial tube type antenna Measurement precision:±3mm
Process temperature:(-40~250)℃ Process pressure:(-0.1~4)MPa
The signal output::(4~20)mA/HART The scene display: four LCD
Power source: two line (DC24V) / four line (DC24V/AC220V)
Shell: Aluminum Process connection: thread / flange (optional)
HYRD705
Suitable medium: Liquid, especially in the environment of high temperature and high pressure liquid
Should use: Sealed cans, liquid measuring pressure
Explosion-proof certification:Exib IIC T6 Gb/
Exd IIC T6 Gb
measuring range :6m
Frequency:500MHz-1.8GHz
Day line:Single rod or a single cable
Measurement precision:±10mm
Process temperature:(-40~250)℃ Process pressure:(-0.1~4)MPa
The signal output::(4~20)mA/HART The scene display: four LCD
Power source: two line (DC24V) / four line (DC24V/AC220V)
Shell: Aluminum Process connection: thread / flange (optional)
Dimensions:
Technical parameters
Basic parameters
Operating frequency: 500MHZ-1.8GHZ
Measuring range: cable type: 0-30m; rod type: 0-6m
Repeat: ± 1mm
Resolution: 1mm
Sample: echo sampling of 55 /s
Response: < 0.2S (according to the specific circumstances)
Output current: 4-20mA
Precision: ± 3mm
The communication interface HART communication protocol
Process connection G1-1/2A thread, flange DN50, DN80, DN100, DN150, DN200, DN250
Process pressure -0.1~4Mpa
Power supply: 24VDC (+ 10%), the ripple voltage: 1Vpp
Power consumption: Max 22.5mA
Environmental conditions The temperature of -40 ℃ ~ +70 ℃
Protection class IP67
Explosion-proof grade Exib II CT6/ Exd II CT6
Cable entrance: 2 M20*1.5 (cable diameter 5--9mm)
Order Selection:
HYRD701
Instrument type The maximum range / probe type
HBRD701 30000mm / Single cable type or single rod
Licence
P normalized form( Non explosion proof )
I Intrinsically safe (Exib IIC T6 Gb)
G Intrinsically safe +Flameproof (Exd〔ib〕IIC T6 Gb)
Probe type/material quality
A Cable type probe Φ8mm /stainless steel 304
B Cable type probe Φ8mm /stainless steel 316L
C Rod type probe Φ12mm/stainless steel 304
D Rod type probe Φ12mm/stainless steel 316L
procedure linkage
G screw thread G1-1/2A
N screw thread 1-1/2’’NPT
C flange DN50 PN16/stainless steel
D flange DN80 PN16/stainless steel
E flange DN100 PN16/stainless steel
F flange DN150 PN16/stainless steel
H flange DN200 PN16/stainless steel
I flange 2〞150LBS Convex/stainless steel 316L
J flange 3〞150LBS Convex/stainless steel 316L
K flange 4〞150LBS Convex/stainless steel 316L
L flange6〞150LBS Convex/stainless steel 316L
M flange8〞150LBS Convex/stainless steel 316L
Seal /Process temperature
1.Ordinary type (-40 ~ 120) ℃
2. High temperature (-40 ~ 250) ℃
Shell / protection class
L aluminum /IP67 Q stainless steel 316L/IP67
Cable line
M M 20x1.5 N 1/2 ’’NPT
Field display
V belt X Without
programming unit
V belt X Without
HYRD702
Instrument type The maximum range / probe type
HBRD702 20000mm / PTFE sealing cable or rod antenna
Licence
P normalized form( Non explosion proof )
I Intrinsically safe (Exib IIC T6 Gb)
G Intrinsically safe+Flameproof (Exd〔ib〕IIC T6 Gb)
Probe type/material quality
A Cable type probe Φ8mm /stainless steel 304
B Cable type probe Φ8mm /stainless steel 316L
C Rod type probe Φ12mm/stainless steel 304
D Rod type probe Φ12mm/stainless steel 316L
procedure linkage
G screw thread G1-1/2A
N screw thread 1-1/2’’NPT
C flange DN50 PN16/stainless steel
D flange DN80 PN16/stainless steel
E flange DN100 PN16/stainless steel
F flange DN150 PN16/stainless steel
H flange DN200 PN16/stainless steel
I flange 2〞150LBS Convex/stainless steel 316L
J flange 3〞150LBS Convex/stainless steel 316L
K flange 4〞150LBS Convex/stainless steel 316L
L flange6〞150LBS Convex/stainless steel 316L
M flange8〞150LBS Convex/stainless steel 316L
Seal /Process temperature
1.Ordinary type (-40 ~ 120) ℃
2. High temperature (-40 ~ 250) ℃
Shell / protection class
L aluminum /IP67 Q stainless steel 316L/IP67
Cable line
M M 20x1.5 N 1/2 ’’NPT
Field display
V belt X Without
programming unit
V belt X Without
HYRD703
Instrument type The maximum range / probe type
HBRD703 30000mm /Double cable
Licence
P normalized form( Non explosion proof )
I Intrinsically safe (Exib IIC T6 Gb)
G Intrinsically safe+Flameproof (Exd〔ib〕IIC T6 Gb)
Probe type/material quality
A Cable type probe Φ8mm /stainless steel 304
B Cable type probe Φ8mm /stainless steel 316L
procedure linkage
G screw thread G1-1/2A
N screw thread 1-1/2’’NPT
C flange DN50 PN16/stainless steel
D flange DN80 PN16/stainless steel
E flange DN100 PN16/stainless steel
F flange DN150 PN16/stainless steel
H flange DN200 PN16/stainless steel
I flange 2〞150LBS Convex/stainless steel 316L
J flange 3〞150LBS Convex/stainless steel 316L
K flange 4〞150LBS Convex/stainless steel 316L
L flange6〞150LBS Convex/stainless steel 316L
M flange8〞150LBS Convex/stainless steel 316L
Seal /Process temperature
1.Ordinary type (-40 ~ 120) ℃
2. High temperature (-40 ~ 250) ℃
Shell / protection class
L aluminum /IP67 Q stainless steel 316L/IP67
Cable line
M M 20x1.5 N 1/2 ’’NPT
Field display
V belt X Without
programming unit
V belt X Without
HYRD704
Instrument type The maximum range / probe type
HBRD704 6000mm / Coaxial tube type antenna
Licence
P normalized form( Non explosion proof )
I Intrinsically safe (Exib IIC T6 Gb)
G Intrinsically safe + Flameproof (Exd〔ib〕IIC T6 Gb)
Probe type/material quality
A Cable type probe Φ12mm /stainless steel 304
B Cable type probe Φ12mm /stainless steel 316L
Procedure linkage
G screw thread G1-1/2A
N screw thread 1-1/2’’NPT
C flange DN50 PN16/stainless steel
D flange DN80 PN16/stainless steel
E flange DN100 PN16/stainless steel
F flange DN150 PN16/stainless steel
H flange DN200 PN16/stainless steel
I flange 2〞150LBS Convex/stainless steel 316L
J flange 3〞150LBS Convex/stainless steel 316L
K flange 4〞150LBS Convex/stainless steel 316L
L flange6〞150LBS Convex/stainless steel 316L
M flange8〞150LBS Convex/stainless steel 316L
Seal /Process temperature
1.Ordinary type (-40 ~ 120) ℃
2. High temperature (-40 ~ 250) ℃
Shell / protection class
L aluminum /IP67 Q stainless steel 316L/IP67
Cable line
M M 20x1.5 N 1/2 ’’NPT
Field display
V belt X Without
programming unit
V belt X Without
HYRD705
Instrument type The maximum range / probe type
HBRD705 6000mm / Single rod or single cable antenna
Licence
P normalized form( Non explosion proof )
I Intrinsically safe (Exib IIC T6 Gb)
G Intrinsically safe + Flameproof (Exd〔ib〕IIC T6 Gb)
Probe type/material quality
A Cable type probe Φ12mm /stainless steel 304
B Cable type probe Φ12mm /stainless steel 316L
Procedure linkage
G screw thread G1-1/2A
N screw thread 1-1/2’’NPT
C flange DN50 PN16/stainless steel
D flange DN80 PN16/stainless steel
E flange DN100 PN16/stainless steel
F flange DN150 PN16/stainless steel
H flange DN200 PN16/stainless steel
I flange 2〞150LBS Convex/stainless steel 316L
J flange 3〞150LBS Convex/stainless steel 316L
K flange 4〞150LBS Convex/stainless steel 316L
L flange6〞150LBS Convex/stainless steel 316L
M flange8〞150LBS Convex/stainless steel 316L
Seal /Process temperature
1.Ordinary type (-40 ~ 400) ℃
Shell / protection class
L aluminum /IP67 Q stainless steel 316L/IP67
Cable line
M M 20x1.5 N 1/2 ’’NPT
Field display
V belt X Without
programming unit
V belt X Without
Previous: No more