This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 30 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.
CONTACT US
INTRODUCTION
Application:Solid particles, Powder
Measuring Range:30 meters
Process Connection:Thread, Flange
Medium Temperature:-40℃~130℃(Standard type)
-40℃~230℃(High temperature type)
Process Pressure:-0.1 ~ 4.0MPa (Flat flange)
-0.1 ~ 0.3MPa (Universal Flange)
Accuracy:± 15mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Supply:2-wire(DC24V)/ 4-wire(DC24V /AC220V)
Outer Covering:Aluminum / Plastic / Stainless steel
Explosion-proof Grade:ExiaⅡC T6 Ga/ Exd ⅡC T6 Gb
FEATURES
Small antenna size, easy to install; Non-contact radar, no wear, no pollution.
Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere,
the temperature and pressure changes.
Serious dust environment on the high level meter work has little effect.
A shorter wavelength, the reflection of solid surface inclination is better.
Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.
The measuring range is smaller, for a measurement will yield good results.
High signal-to-noise ratio, the level fluctuation state can obtain better performance.
High frequency, measurement of solid and low dielectric constant of the best choice.
STRUCTURE SIZE (mm)
Out shell
Appearance size
Technical Parameters
Items | Description | Remarks |
Process Connection | Thread G1½″A / Thread 1½″ NPT / Flange | |
Antenna Material | Stainless Steel / PTFE | |
Power Supply | (16 ~ 26) V DC | standard type |
(21.6 ~ 26.4) V DC | Intrinsically safe | |
(110 ~242)V AC | 4 wire system | |
Output | 4-20mA/ Hart, RS485 | |
The integral time | 0~36S adjustable | |
Max range | 30Meters | |
Display resolution | 1mm | |
Process temperature | (40~130)℃ | |
Pressure | Max.4MPa |
Model Selection
HYRD905 | Code Selection | Remarks | |||||||
Range | 0~30M(pls adv range needed) | ||||||||
Antenna Type | G | Thread G1½″ A | |||||||
N | Thread 1½″ NPT | ||||||||
A | Flange DN80 /SS304 | ||||||||
B | Flange DN100 /SS304 | ||||||||
C | Flange DN125 /SS304 | ||||||||
D | Flange DN150 /SS304 | ||||||||
M | Universal Flange DN80 /SS304 | ||||||||
K | Universal Flange DN100 /SS304 | ||||||||
T | Universal Flange DN125 /SS304 | ||||||||
Z | Universal Flange DN150 /SS304 | ||||||||
Antenna type/Material | A | Horn Antenna Φ76mm / SS316L | |||||||
B | Horn Antenna Φ96mm / SS316L | ||||||||
C | Horn Antenna Φ121mm / SS316L | ||||||||
Y | Special Request | ||||||||
Output and power supply | 3 | (4~20) mA / 24V DC / HART 2 wire | |||||||
4 | (4~20) mA / 220V AC / HART 4 wire | ||||||||
5 | RS485 Modbus / 6~24V/ 4 wire | ||||||||
Enclosure and protection | L | Aluminum / Single chamber / IP67 | |||||||
H | Aluminum / Double chamber / IP67 | ||||||||
G | Plastic / Single chamber / IP65 | ||||||||
K | Stainless steel / Single chamber / IP67 | ||||||||
Cable Entry | M | M20 X 1.5 | |||||||
N | 1/2NPT | ||||||||
LCD display | A | With | |||||||
X | Without |
Application:
HYRD905 used for cement powder 12meters